Home Up Control-IT English Reactie Inhoud
Control-IT Industrie Automatisering,  MES, SCADA en OPC consultancy.

Up

 

Cimplicity

Ontwikkelaar :

Cimplicity wordt ontwikkeld door GE-Fanuc. GE-Fanuc is een joint venture van General Electric Company en FANUC LTD in Japan. Hoofdkantoor in Charlottesville, Virginia. GE Fanuc is onder andere ook leverancier van de 90-series PLC's.

Website GE Fanuc: http://www.geindustrial.com/cwc/gefanuc/TopBarProducts.html

Vertegenwoordiging in Nederland :

Novotek BV
Takkebijsters 9
4817 BL  Breda
tel :  0765871010
Fax :  0765810111
Web Site : http://www.novotek.nl

Versie per 1/2 2002 :

CIMPLICITY Machine Edition versie 3.

CIMPLICITY® HMI Plant Edition™.versie 6.1

 

Pakketbeschrijving :

Cimplicity komt in twee soorten : ME (Machine Edition) en PE (Plant Edition). De machine Edition is een  HMI versie met geintegreerde controlprogrammeersoftware en motion programmeersoftware en daarmee een combinatie van soft-logic en SCADA. De Plant Edition is het uiteindelijke uitgebreide SCADA produkt.  Plant edition en Machine Edition zijn totaal verschillende pakketten en kunnen niet gemakkelijk in elkaar worden overgezet. De rest van deze pagina richt zich op Plant Edition

Key selling points (HMI Plant Edition):

  • Geschikt voor 50 tot oneindig I/O
  • Visual Basic Scripting
  • Visual Basic control engine
  • Server/Client architectuur. Servers en viewers bieden een systeem uitbreiding om data te delen met meerdere gebruikers
  • Tools: Point Control Panel, Point Cross Reference, Point View en System Sentry
  • 14 applicatie opties bieden geavanceerde oplossingen van SPC en recepten tot redundantie.
  • Andere features:
    - ActiveX, OPC, COM & DCOM
    - Voorgedefineerde Objecten (SmartObjects)
    - Object georiėnteerd met drag and drop
    - Alarm Manager en Viewer
    - Action Calendar (Event Sceduler)
  • VCR service

 

Architecture (HMI Plant Edition)

Cimplicity is based on a client–server architecture consisting of Servers and Viewers. Servers are responsible for the collection and distribution of data. Viewers connect into Servers and have full access to the collected data for viewing and control actions.

Processing of data (Data Access, Alarm management and Trending) is performed locally in the so-called Real Time Point Database for external data points that are collected from the PLC by the local computer.
Persisting data (Historical Trending, Alarm history) is stored local or networked in a MSDE Database in a readable format. This MSDE database is accessible for third party applications.
Clients addresses data points with \\Server\datapointID.attribute.
There are two types of data points:

1. Device points read from and/or write to devices
2. Virtual points do not directly originate from devices.

A data point has beside the Present value several attributes, like alarm configuration data, trend configuration, quality, timestamp.



Basic architecture of a server

 

Licentieopbouw

Servers can be licensed to collect data from 75, 150, 300, 700, 1500 or an unlimited number of device points. Exempted from the point count are virtual points, which reside only in the computer and points collected by another server.
Possible choices are between a Runtime or a Development system and between a Server an a Viewer
Viewers can attach to unequal servers, so one viewer of 300 data point can attach to two 150 data points servers
 

Suite products/Add ons

  • Cimplicity Tracker :  Work In Progress  tracking en routing van discrete produktie. Management software voor inventarisatie naar aantallen en plaats en plannen van produktiemiddelen.
  • Cimplicity WebView Converting tool van graphics naar webpagina's
  • Cimplicity Manager (Software versie manager)
  • Cimplicity SPC (Statistical Process Control)
  • Cimplicity OpenProcess (Soft logic controller)
  • Cimplicity Advantage (MES)

Referenties

  • procesvisualisering van het energiemanagement voor de warmte- en elektriciteitsvoorziening bij het RIVM (EKB)
  •  

 