WinCC

Ontwikkelaar :

Win CC wordt ontwikkeld door Siemens AG afdeling Automation and Drives - SIMATIC Human Machine Interface in Nuernberg.

WinCC website : http://www.ad.siemens.de/hmi/html_76/products/software/wincc/index.htm

Vertegenwoordiging in Nederland :

Siemens Nederland N.V.

Den Haag

http://www.siemens.nl/ind_portal/default.asp?navid=161

Versie per eind 2004 :

Versie 6.0 sp2

Pakketbeschrijving :

WinCC van Siemens staat voor de afkorting voor Windows Control Center. Het systeem is geďntegreerd in het SIMATIC procesbeheersingssysteem PCS 7 (onder andere de programmeertaal van de PLC's) . De integratie van de systemen maakt gebruik mogelijk van data uit de gemeenschappelijke database met andere PCS7 componenten.

Key selling points

  • Geďntegreerd in het SIMATIC procesbeheersingssysteem PCS 7
  • client/server-structuur
  • Historian in standaardlicentie
  • Projecttaal is on line om te schakelen.
  • OPC drivers
  • Enige 3trd. party drivers
  • Redundantie mogelijkheden
  • Global Script in ANSI-C. Dit is te koppelen per object of als tijdsafhankelijke actie.
  • Driver ontwikkeling via CDK (Channel Development Kit, optioneel)

Architecture

WinCC is based on a concept of a local data engine on the IO server whereby additional some servers for dedicated tasks can be used (long term logging, configuration server etc).

Runtime database:

Since version 6 Siemens left the use of a Sybase database to store runtime data. Now the runtime data is distributed on the master configuration database (MS SQL server) and several runtime databases on the (IO) server. A WinCC has a standard on-board historian (SQL server).

An (IO) server within a WinCC network can fulfill the following tasks:
• Connection to the process
• Acquisition of the process values
• Archiving messages and process values
• Providing clients with data from the process
• Providing clients with the configuration data

WinCC can be used to configure client-server systems having several (IO) servers enabling larger systems to be operated and monitored (multi (IO) server system).

Clients:


Clients can be used for:
• Multi-user systems with one server to configure: Several clients access the project on a server with process driver connection. In the case of a multi-user system, it is not necessary to configure the clients because all data is provided by the server.
• Distributed systems with several servers to configure: Clients can display the data from different servers with process driver connection. Within a distributed system, each client has an individual configuration; the necessary server data is imported on the clients and, if modified, can be automatically updated. The process data is provided by the servers.


Configuration:

The configuration data is saved in a single database. The configuration database is created in a project directory. The file assumes the project name as the file name.
WinCC V 6 Server manages runtime data and configuration data with the Microsoft SQL Server 2000.
WinCC V6.0 only operates with cyclic archives, as in V5 the runtime data was stored in sequence archives and cyclic archives in a common database.
 


Various systemcomponents of WinCC

 

Licentieopbouw

Authorization is effected during the installation process with a special authorization diskette. Alternatively, the authorization can be installed later by the user with the AuthorsW program.

A distinction is made here between RC licenses (Runtime and Configuration) and pure RT licenses (only runtime).

The classification of the licenses relates to the maximum number of process tags and archive tags. Process tags are PLC data points, archive tags are historical trend tags.
With the authorization RC 1024 PTg 512 Atag, for example, up to 1024 process tags and 512 archive tags can be configured.

Process tags

The following packages for runtime (RT) and complete systems (RC) are available according to the size of the project to be realized:
128, 256, 1024, 8K and 64K Process tags

Archive tags

The basic license WinCC (RT, RT/CS) contains 512 free archive tags and any number of messages possible (messages are alarm configuration records)
The number of archive tags can be extended to 1500, 5000, 30,000 and 80,000 (sp2) tags by means of power packs.

Process tags needed for the WinCC channel "System Info" are License-free. Other internal tags are counted within the license.

 

Suite products

  • geďntegreerd met de PCS7 Simatic lijn
  • diverse produkten (bijv MES, ERP koppelingen)